GP Structural Services was engaged to investigate structural concerns within wet area slabs at a residential property in Angle Vale. Initial assessments by the client’s consulting engineer suggested potential non-compliance with design specifications. A detailed GPR concrete scan was required to confirm slab thickness, reinforcement placement, and to identify any deficiencies that could compromise performance and safety.
Concrete Scanning Investigation
Execution of Remedial Works
Quality & Compliance
The remediation process successfully rectified the undersized slab sections, restoring compliance with the engineering design and Australian Standards. By preserving the original footings while replacing only the defective slab sections, the works provided a cost-effective and structurally sound outcome.
This project highlights GP Structural Services’ ability to combine investigation with remediation, offering clients a complete service — from diagnosis of the problem through to engineered repair and certification.